Posted  by  admin

Solar Farm Kv Harmonic Filter

Solar Farm Kv Harmonic Filter 6,0/10 6698 reviews

Modern solar inverters use maximum power point (MPP) trackers, which generate disturbances into both the grid’s AC power line and the DC side of the solar module.Installers will usually place filters on the grid’s AC power line, but it’s often forgotten that there is also noise generated on the DC. Dynamics of the solar farm through various control scenarios can be achieved. Scaling Component: This component is used to model several units of inverters in a solar farm. In this example, the solar farm consists of 100 units. Figure 1 shows the overall layout of the integration of the solar farm into an existing electrical network.

Mar 07, 2018  scarica euro truck simulator 2 versione completa gratis, download euro truck simulator 2 full version, download euro truck simulator 2 multiplayer, download euro truck simulator 2 free, download. Download

PV ArrayThe PV array consists of 86 parallel strings. Each string has 7 SunPower SPR-415E modules connected in series. Note that the model menu allows you to plot the I-V and P-V characteristics of the selected module or of the whole array. Three-phase DC/AC ConverterThe converter is modeled using a 3-level IGBT bridge PWM-controlled. The inverter choke RL and a small harmonics filter C are used to filter the harmonics generated by the IGBT bridge. A 250-kVA 250V/25kV three-phase transformer is used to connect the inverter to the utility distribution system.

Harmonic filters for power

Inverter ControlThe control system contains five major Simulink®-based subsystems.MPPT Controller: The Maximum Power Point Tracking (MPPT) controller is based on the 'Perturb and Observe' technique. This MPPT system automatically varies the VDC reference signal of the inverter VDC regulator in order to obtain a DC voltage which will extract maximum power from the PV array.VDC Regulator: Determine the required Id (active current) reference for the current regulator.Current Regulator: Based on the current references Id and Iq (reactive current), the regulator determines the required reference voltages for the inverter.

In our example, the Iq reference is set to zero.PLL & Measurements: Required for synchronization and voltage/current measurements.PWM Generator: Generate firing signals to the IGBTs based on the required reference voltages. In our example, the carrier frequency is set to 1980 Hz (33.60).Utility GridThe grid is modeled as a typical North American distribution grid.

Solar Farm Kv Harmonic FilterSolar farm kv harmonic filter diagram

Solar Farm Kv Harmonic Filter Reviews

It included two 25-kV feeders, loads, grounding transformer and an equivalent 120-kV transmission system. SimulationRun the simulation and observe the resulting signals on the various scopes.The initial input irradiance to the PV array model is 1000 W/m2 and the operating temperature is 45 deg. When steady-state is reached (around t=0.15 sec.), we get a PV voltage (Vdcmean) of 481 V and the power extracted (Pdcmean) from the array is 236 kW. These values correspond very well to the expected values from the PV module manufacturer specifications.At t=0.3 sec, sun irradiance is rapidly ramped down from 1000 W/m^2 to 200 W/m^2. Due to the MPPT operation, the control system reduces the VDC reference to 464 V in order to extract maximum power from the PV array (46 kW).